Modified on Fri, 20 Sep, 2024 at 9:37 AM

  • Start regedit: Navigate to HKEY_LOCAL_MACHINE \ SOFTWARE \ iba \ ibaPDA
  • Create a DWORD key with the name AcqThreadCycleTime and set the value to 10, which is the minimum value allowed. 
  • Restart the ibaPDA server. 
  • Check the server log file: there should be a message like "Acquisition thread is running with a cycle time of..." Note: the 50ms display will not change. The change in the registry is not supported (this will be corrected in version 6.39).


 